Skip Ribbon Commands
Skip to main content
Sign In

Item

 

 

Lab Analysishttps://schroederindustries.com/sites/authoring/Lists/Products/DispForm.aspx?ID=189Lab Analysis

Overview
Downloads
Contact

 

 

Lab Analysishttps://schroederindustries.com/sites/authoring/Lists/Products/DispForm.aspx?ID=189Lab Analysis<div class="ExternalClassC58DA180EF0D4436B33508F4E958ACFB"><div class="pdb-text-wrap" style="width:714px;height:auto;text-align:left;"> Fuel analysis can identify potential causes for fuel filter plugging, smoking, loss of power, poor injector performance, malfunctioning throttle position sensors and sticking valves. Testing also confirms a diesel fuel's sulfur content, biodiesel content and compliance with manufacturer specifications and standards for cleanliness that could affect equipment warranty requirements. <p> </p>​ <p>Schroeder Industries offers Troubleshooting and Diesel fuel quality test packages. All packages include pre-paid testing and the required number of fuel containers for sample.</p><p> </p><table width="100%" class="ms-rteTable-default" cellspacing="0" style="font-size:1em;"><tbody><tr class="ms-rteTableHeaderRow-default"><th class="ms-rteTableHeaderEvenCol-default" rowspan="1" colspan="1">​<strong>Contamination Tests </strong>       Schroeder P/N: 02098006</th><th class="ms-rteTableHeaderOddCol-default" rowspan="1" colspan="1">Includes ​</th><th class="ms-rteTableHeaderEvenCol-default" rowspan="1" colspan="1">Sample Amount​</th></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableEvenCol-default" rowspan="2" colspan="1">​​Identifies contamination from external sources - <br>oil, biological growth, water, sediment</td><td class="ms-rteTableOddCol-default">​ICP</td><td class="ms-rteTableEvenCol-default">​2 mL</td></tr><tr class="ms-rteTableEvenRow-default"><td class="ms-rteTableEvenCol-default">​Flash Point</td><td class="ms-rteTableOddCol-default">​200 mL</td></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableEvenCol-default" rowspan="3" colspan="1">​I​dentifies contamination to be the result of a change in the fuel’s physical properties - <br>low thermal stability may require use of an asphaltene conditioner ​</td><td class="ms-rteTableOddCol-default">​Thermal Stability</td><td class="ms-rteTableEvenCol-default">​120 mL</td></tr><tr class="ms-rteTableEvenRow-default"><td class="ms-rteTableEvenCol-default">​Water and Sediment</td><td class="ms-rteTableOddCol-default">​200 mL</td></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableEvenCol-default">​Bacteria, Fungi, Mold</td><td class="ms-rteTableOddCol-default">​120 mL</td></tr></tbody></table><p> </p><table width="100%" class="ms-rteTable-default" cellspacing="0" style="font-size:1em;"><tbody><tr class="ms-rteTableHeaderRow-default"><th class="ms-rteTableHeaderEvenCol-default" rowspan="1" colspan="1">​<strong>Smoking Tests </strong>                Sc<span>​</span><span>​</span><span>​</span><span>​</span>hroeder P/N: 02098007</th><th class="ms-rteTableHeaderOddCol-default" rowspan="1" colspan="1">​Includes </th><th class="ms-rteTableHeaderEvenCol-default" rowspan="1" colspan="1">​Sample Amount</th></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableEvenCol-default" rowspan="2" colspan="1">​Identifies low cetane index or water contamination - <br>loss of power, white smoke</td><td class="ms-rteTableOddCol-default">​Sulfur</td><td class="ms-rteTableEvenCol-default">​50 mL</td></tr><tr class="ms-rteTableEvenRow-default"><td class="ms-rteTableEvenCol-default">​Cetane Index</td><td class="ms-rteTableOddCol-default">​100 mL</td></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableEvenCol-default" rowspan="3" colspan="1">Identifies excessive sulfur content - black smoke​ ​ ​</td><td class="ms-rteTableOddCol-default">​API Gravity</td><td class="ms-rteTableEvenCol-default">​400 mL</td></tr><tr class="ms-rteTableEvenRow-default"><td class="ms-rteTableEvenCol-default">​Distillation</td><td class="ms-rteTableOddCol-default">​200 mL</td></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableEvenCol-default">​Water and Sediment</td><td class="ms-rteTableOddCol-default">​200 mL</td></tr></tbody></table><p> </p><table width="100%" class="ms-rteTable-default" cellspacing="0" style="font-size:1em;"><tbody><tr class="ms-rteTableHeaderRow-default"><th class="ms-rteTableHeaderFirstCol-default" rowspan="1" colspan="1">​<strong>Filter Plugging Tests</strong>       Schroeder P/N: 02093395</th><th class="ms-rteTableHeaderOddCol-default" rowspan="1" colspan="1">​Includes</th><th class="ms-rteTableHeaderEvenCol-default" rowspan="1" colspan="1">​Sample Amount</th></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableFirstCol-default" rowspan="3" colspan="1">​I​dentifies contamination from external sources <br>specific to filter plugging  - high particle count, <br>biological growth</td><td class="ms-rteTableOddCol-default">​Thermal Stability</td><td class="ms-rteTableEvenCol-default">​120 mL</td></tr><tr class="ms-rteTableEvenRow-default"><td class="ms-rteTableFirstCol-default">​Bacteria, Fungi, Mold</td><td class="ms-rteTableOddCol-default">​120 mL</td></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableFirstCol-default">​Pour Point</td><td class="ms-rteTableOddCol-default">​100 mL</td></tr><tr class="ms-rteTableEvenRow-default"><td class="ms-rteTableFirstCol-default" rowspan="3" colspan="1">Identifies contamination due to a change in <br>the fuel’s physical properties - low thermal stability or <br>insufficient cold weather capability for operating environment</td><td class="ms-rteTableOddCol-default">​Cloud Point</td><td class="ms-rteTableEvenCol-default">​100 mL</td></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableFirstCol-default">​Cold Filter Plug Point</td><td class="ms-rteTableOddCol-default">​100 mL</td></tr><tr class="ms-rteTableEvenRow-default"><td class="ms-rteTableFirstCol-default">​Particle Count</td><td class="ms-rteTableOddCol-default">​80 mL</td></tr></tbody></table><p> </p><table width="100%" class="ms-rteTable-default" cellspacing="0" style="font-size:1em;"><tbody><tr class="ms-rteTableHeaderRow-default"><th class="ms-rteTableHeaderEvenCol-default" rowspan="1" colspan="1"> <strong>​</strong><strong>Cleanliness Tests</strong>                     Schroeder P/N: 02098008</th><th class="ms-rteTableHeaderOddCol-default" rowspan="1" colspan="1">​Includes</th><th class="ms-rteTableHeaderEvenCol-default" rowspan="1" colspan="1">Sample Amount​</th></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableEvenCol-default" rowspan="1" colspan="1">​Identifies water contamination - <br>can lead to smoking, biological growth and corrosion</td><td class="ms-rteTableOddCol-default">​Karl Fischer</td><td class="ms-rteTableEvenCol-default">​10 mL</td></tr><tr class="ms-rteTableFooterRow-default"><td class="ms-rteTableFooterEvenCol-default" rowspan="1" colspan="1">​Identifies particulate contamination - can result in <br>extreme wear in high pressure fuel systems which <br>may cause premature injector failure</td><td class="ms-rteTableFooterOddCol-default" rowspan="1">​Particle Count</td><td class="ms-rteTableFooterEvenCol-default" rowspan="1">​80 mL</td></tr></tbody></table><p> </p><table width="100%" class="ms-rteTable-default" cellspacing="0" style="font-size:1em;"><tbody><tr class="ms-rteTableHeaderRow-default"><th class="ms-rteTableHeaderFirstCol-default" rowspan="1" colspan="1">​<strong>Wear Prevention Tests</strong>          Schroeder P/N: 02098009</th><th class="ms-rteTableHeaderOddCol-default" rowspan="1" colspan="1">​Includes</th><th class="ms-rteTableHeaderEvenCol-default" rowspan="1" colspan="1">​Sample Amount</th></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableFirstCol-default" rowspan="3" colspan="1">​​Identifies cause of wear - water contamination, <br>excessive particles or insufficient lubricity</td><td class="ms-rteTableOddCol-default">​Karl Fischer</td><td class="ms-rteTableEvenCol-default">​10 mL</td></tr><tr class="ms-rteTableEvenRow-default"><td class="ms-rteTableFirstCol-default">​Particle Count</td><td class="ms-rteTableOddCol-default">​80 mL</td></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableFirstCol-default">​Lubricity</td><td class="ms-rteTableOddCol-default">​20 mL</td></tr></tbody></table><p> </p><p> </p><table width="100%" class="ms-rteTable-default" cellspacing="0" style="font-size:1em;"><tbody><tr class="ms-rteTableHeaderRow-default"><th class="ms-rteTableHeaderFirstCol-default" rowspan="1" colspan="1"> <strong>​</strong><strong>Summer Tests</strong>                        Schroeder P/N: 02098010</th><th class="ms-rteTableHeaderOddCol-default" rowspan="1" colspan="1">​Includes</th><th class="ms-rteTableHeaderEvenCol-default" rowspan="1" colspan="1">​Sample Amount</th></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableFirstCol-default" rowspan="5" colspan="1">​Identifies contamination from external sources - <br>oil, biological growth, water, sediment</td><td class="ms-rteTableOddCol-default">​Flash Point</td><td class="ms-rteTableEvenCol-default">​200 mL</td></tr><tr class="ms-rteTableEvenRow-default"><td class="ms-rteTableFirstCol-default">​Water and Sediment</td><td class="ms-rteTableOddCol-default">​200 mL</td></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableFirstCol-default">​Kinematic Viscosity</td><td class="ms-rteTableOddCol-default">​2 mL</td></tr><tr class="ms-rteTableEvenRow-default"><td class="ms-rteTableFirstCol-default">​Sulfur</td><td class="ms-rteTableOddCol-default">​50 mL</td></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableFirstCol-default">​Cetane Index</td><td class="ms-rteTableOddCol-default">​100 mL</td></tr><tr class="ms-rteTableEvenRow-default"><td class="ms-rteTableFirstCol-default" rowspan="5" colspan="1">​Identifies contamination to be the result of a change in the <br>fuel’s physical properties - low thermal stability may require <br>use of an asphaltene conditioner</td><td class="ms-rteTableOddCol-default">​API Gravity</td><td class="ms-rteTableEvenCol-default">​400 mL</td></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableFirstCol-default">​Distillation</td><td class="ms-rteTableOddCol-default">​200 mL</td></tr><tr class="ms-rteTableEvenRow-default"><td class="ms-rteTableFirstCol-default">​Thermal Stability</td><td class="ms-rteTableOddCol-default">​120 mL</td></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableFirstCol-default">​Bacteria, Fungi, Mold</td><td class="ms-rteTableOddCol-default">​120 mL</td></tr><tr class="ms-rteTableEvenRow-default"><td class="ms-rteTableFirstCol-default" rowspan="1">​ICP</td><td class="ms-rteTableOddCol-default" rowspan="1">​2 mL</td></tr></tbody></table><p> </p><table width="100%" class="ms-rteTable-default" cellspacing="0" style="font-size:1em;"><tbody><tr class="ms-rteTableHeaderRow-default"><th class="ms-rteTableHeaderEvenCol-default" rowspan="1" colspan="1">​<strong>Winter Tests</strong>                          Schroeder P/N:  02098011</th><th class="ms-rteTableHeaderOddCol-default" rowspan="1" colspan="1">Includes​</th><th class="ms-rteTableHeaderEvenCol-default" rowspan="1" colspan="1">Sample Amount​</th></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableEvenCol-default" rowspan="6" colspan="1">​Identifies low cetane index or water contamination - <br>loss of power, white smoke</td><td class="ms-rteTableOddCol-default">​Flash Point</td><td class="ms-rteTableEvenCol-default">​200 mL</td></tr><tr class="ms-rteTableEvenRow-default"><td class="ms-rteTableEvenCol-default">​Water and Sediment</td><td class="ms-rteTableOddCol-default">​200 mL</td></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableEvenCol-default">​Kinematic Viscosity</td><td class="ms-rteTableOddCol-default">​2 mL</td></tr><tr class="ms-rteTableEvenRow-default"><td class="ms-rteTableEvenCol-default">​Sulfur</td><td class="ms-rteTableOddCol-default">​50 mL</td></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableEvenCol-default">​Cetane Index</td><td class="ms-rteTableOddCol-default">​100 mL</td></tr><tr class="ms-rteTableEvenRow-default"><td class="ms-rteTableEvenCol-default">​API Gravity</td><td class="ms-rteTableOddCol-default">​400 mL</td></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableEvenCol-default" rowspan="6" colspan="1">​Identifies excessive sulfur content - black smoke</td><td class="ms-rteTableOddCol-default">​Distillation</td><td class="ms-rteTableEvenCol-default">​200 mL</td></tr><tr class="ms-rteTableEvenRow-default"><td class="ms-rteTableEvenCol-default">​Thermal Stability</td><td class="ms-rteTableOddCol-default">​120 mL</td></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableEvenCol-default">​Pour Point</td><td class="ms-rteTableOddCol-default">​100 mL</td></tr><tr class="ms-rteTableEvenRow-default"><td class="ms-rteTableEvenCol-default" rowspan="1">​Cloud Point</td><td class="ms-rteTableOddCol-default" rowspan="1">​100 mL</td></tr><tr class="ms-rteTableOddRow-default"><td class="ms-rteTableEvenCol-default" rowspan="1">​Bacteria, Fungi, Mold</td><td class="ms-rteTableOddCol-default" rowspan="1">​120 mL</td></tr><tr class="ms-rteTableFooterRow-default"><td class="ms-rteTableFooterEvenCol-default" rowspan="1">​ICP</td><td class="ms-rteTableFooterOddCol-default" rowspan="1">​2 mL</td></tr></tbody></table><p> </p></div></div>