Skip Ribbon Commands
Skip to main content
Sign In

Item

 

 

FCU: FluidControlUnit Serieshttps://schroederindustries.com/sites/authoring/Lists/Products/DispForm.aspx?ID=375FCU: FluidControlUnit Series

Overview
Downloads
Contact

 

 

FCU: FluidControlUnit Serieshttps://schroederindustries.com/sites/authoring/Lists/Products/DispForm.aspx?ID=375FCU: FluidControlUnit Series<div class="ExternalClassD73AB688D137456186FE01395ECE1C4D"><p>​</p><div class="pdb-text-wrap" style="width:432px;height:auto;text-align:left;"><div class="pdb-subtext-wrap"><p>The FluidControl Unit FCU 1000 is a portable service unit, designed for the temporary measurement of solid particle contamination, water saturation and fluid temperature in hydraulic systems as well as Diesel fuels.</p><p>The integrated pump and the hoses contained in the FCU 1000 series scope of delivery allow operation in control circuits (oil hydraulics only), pressure circuits (oil hydraulics only) and pressureless reservoirs (oil hydraulics and Diesel fuels).</p><p>All measurement values can be transmitted to a PC or mobile devices and analyzed using Schroeder's own Fluid Monitoring Software (FluMoS).</p><br><h3>Features:</h3><ul class="content-box-middle"><li>Suitable for hydraulic fluids up to 350 mm<sup>2</sup>/s</li><li>Suitable for Diesel fuels (suction mode only) according to DIN EN 590 and ASTM D975 4-D</li><li>Cleanliness classes to ISO and SAE or NAS</li><li>Integrated data interfaces (wireless and cable) for direct connection to Schroeder's Fluid Monitoring Software (FluMoS)</li><li>USB interface for data storage</li><li><span aria-hidden="true"><span aria-hidden="true"><a href="https://play.google.com/store/apps/details?id=de.hydac.flumos&hl=de"><img src="/sites/authoring/ProductImage/FluMoS%2016x%20mobile.png" alt="" style="margin:5px;width:52px;vertical-align:middle;float:none;" /></a><span aria-hidden="true"></span><span aria-hidden="true">Usable with FluMoS Mobile App</span></span></span></li></ul><h3>Applications:</h3><ul class="content-box-middle" style="width:433px;height:auto;"><li>Hydraulic systems</li><li>Diesel storage, diesel transfer and diesel filling applications, e.g. mines, refineries, ports of transshipment, emergency power systems (emergency power units), mobile machines, etc.</li><li>Service</li><li>Maintenance</li></ul></div><h3>Specifications:</h3><table class="productSpec "><tbody><tr><td>Self-Diagnosis:</td><td>Continuously with error indication via status LED and display </td><td colspan="1">​</td></tr><tr style="background-color:#f9f9f9;"><td>Measured Value:</td><td>ISO code / SAE Class / NAS Class / Saturation level / Temperature</td><td colspan="1">​</td></tr><tr><td>Measuring Range:</td><td>Display from ISO code 9/8/7 (MIN) to ISO code 25/24/23 (MAX); Calibrated within the range ISO 13/11/10 to 23/21/18; Saturation level 0 to 100 %; Temperature -13°F to 212°F (–25°C to 100°C)</td><td colspan="1">​</td></tr><tr style="background-color:#f9f9f9;"><td>Accuracy:</td><td><p>± 1/2 ISO class in the calibrated range<br>Water saturation: ± maximal 2% (full scale)</p></td><td colspan="1">​</td></tr><tr><td>Material of Sealing:</td><td>FPM Viton seals</td><td colspan="1">​</td></tr><tr style="background-color:#f9f9f9;"><td>Ambient Temperature Range:</td><td>32°F to 113°F (0°C to 45°C)</td><td colspan="1">​</td></tr><tr><td>Storage Temperature Range:</td><td>-40°F to 176°F (-40°C to +80°C)</td><td colspan="1">​</td></tr><tr style="background-color:#f9f9f9;"><td>IP Class:</td><td>IP50 in operation IP67 closed</td><td colspan="1">​</td></tr><tr><td>Weight:</td><td>(FCU 1315) Approx. 29 lbs (13 kg)<br>(FCU 1210) Approx. 20 lbs (9 kg)</td><td colspan="1">​</td></tr></tbody></table><br><h3>Hydraulic Data</h3><table class="productSpec "><tbody><tr style="background-color:#f9f9f9;"><td>Operating Pressure with Hydraulic Fluids:</td><td>IN: -7.25 to 650 psi (-0.5 to 45 bar)<br> OUT: 0 to 7.5 psi (0 to 0.5 bar)</td></tr><tr style="background-color:#f9f9f9;"><td>with Adapter for Pressure Lines:</td><td>IN: 217 to 5000 psi (15 to 345 bar) OUT: 0 to 7.5 psi (0 to 0.5 bar)</td></tr><tr style="background-color:#f9f9f9;"><td rowspan="1">​with Diesel according to DIN EN 590 / ASTM D975 4-D:</td><td rowspan="1">​IN: 0 psi (0 bar) <br>OUT: 0 psi (0 bar)</td></tr><tr style="background-color:#f9f9f9;"><td>Pressure Max.:</td><td>5000 psi (345 bar) (using included high pressure adapter)</td></tr><tr style="background-color:#f9f9f9;"><td>Maximum Suction Height:</td><td>19.69 in (0.5 m)</td></tr><tr style="background-color:#f9f9f9;"><td>Permissible Viscosity Range:</td><td>33 to 1622 SUS (1.5 to 350 cSt)</td></tr><tr style="background-color:#f9f9f9;"><td>Fluid Temperature Range:</td><td>32°F to 158°F (0°C to +70°C)</td></tr></tbody></table><br><h3>Electrical Data</h3><table class="productSpec" border="1"><tbody><tr style="background-color:#f9f9f9;"><td>Power Supply Voltage:</td><td>24 VDC ± 20%, residual ripple < 10%</td></tr><tr style="background-color:#f9f9f9;"><td>Max. Power/Current Consumption:</td><td>100 Watt/4A</td></tr><tr style="background-color:#f9f9f9;"><td>Interface:</td><td>USB for memory stick and 5 pole, m12x1, pin Bluetooth 1.2, Class 3 (only Sensor Interface - HSI)</td></tr></tbody></table><p><br><br></p></div><div class="ExternalClass19646877714A49798634F4A16AA06D22"><div style="width:60%;height:auto;text-align:left;"><div><div><div class="pdb-content-text"><span aria-hidden="true"></span>                                 </div></div></div></div></div></div>

 

 

 

 

FCU_1000_Serieshttps://schroederindustries.com/sites/authoring/ProductImage/Forms/DispForm.aspx?ID=575&RootFolder=/sites/authoring/ProductImageFCU_1000_Series575

 

 

Catalog Pageshttps://schroederindustries.com/sites/authoring/Lists/ProductLinks/DispForm.aspx?ID=239 Catalog Pageshttps://schroederindustries.com/sites/authoring/Literature/FCU1000Series_catalogPgs.pdf#search=FCU, Catalog Pages